Miele T1 Code F2: open circuit on the refrigerant temperature sensor
Miele T1 heat-pump dryers, including the TXD 160 WP and TWB 120 WP, show F2 when the refrigerant temperature sensor is open-circuited. That is the opposite of a short: the sensor or its wiring has lost…
- Code
- F2
- Appliance
- Dryer
- Brand
- Miele
- Warranty
- 30-day workmanship
What F2 means
Miele T1 heat-pump dryers, including the TXD 160 WP and TWB 120 WP, show F2 when the refrigerant temperature sensor is open-circuited. That is the opposite of a short: the sensor or its wiring has lost continuity, so the control receives no usable signal from the heat-pump circuit. The dryer stops the program and shows F2. On the older T 9800 dryers F2 means something else, so the platform matters.
Common causes of F2
- A refrigerant temperature sensor that has gone open
- A broken sensor wire or a connector that came loose
- A control board input that is not reading the sensor
1. Turn the dryer off, wait a minute, and turn it on again. 2. Clean both lint filters and empty the condensate container, since a clean machine runs more predictably. 3. Run a short program. 4. If F2 shows again, leave the dryer off and call us. Please do not remove the lower panel or touch the heat-pump section.
- The heat-pump section holds refrigerant lines that are sealed and off limits to owners.
- An open sensor looks like a broken lead, and a meter is the only way to tell.
- We quote the price in writing before any part is ordered.
- What we fix comes with a 30-day workmanship warranty.
Technical reference
- Code
- F2
- Appliance
- Miele dryer
- Maker documentation
- Miele owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Miele.
Other Dryer codes
What is the difference between F1 and F2 on my T1?
Both involve the refrigerant temperature sensor. F1 reports a short circuit and F2 reports an open circuit. The cure for each starts with checking that sensor and its wiring.
Will cleaning the filters clear F2?
Clean filters help the dryer run well, but they do not fix a sensor that has lost its circuit. If F2 survives a power cycle, the cause is electrical and needs a technician.
How long does a repair like this take?
Most sensor jobs fit one visit once the part is on hand. We diagnose first, tell you the price in writing, and only then start the work.