Miele T1 Code F156: sensor downstream of the condenser shorted

On Miele T1 heat-pump dryers such as the TXD 160 WP or TWI 180 WP, F156 means the refrigerant temperature sensor downstream of the condenser is short-circuited. This sensor sits after the condenser in the heat-pump…

Medium · inspection needed
Code
F156
Appliance
Dryer
Brand
Miele
Warranty
30-day workmanship

What F156 means

On Miele T1 heat-pump dryers such as the TXD 160 WP or TWI 180 WP, F156 means the refrigerant temperature sensor downstream of the condenser is short-circuited. This sensor sits after the condenser in the heat-pump loop and tells the control how the refrigerant is behaving. A shorted reading cannot be used, so the dryer stops the program and shows F156 on the display.

Common causes of F156

  • A short circuit in the sensor downstream of the condenser
  • Damaged wiring or a pinched connector at that sensor
  • A control input misreading the sensor
✓ One safe check you can try

1. Switch the dryer off for a minute, then on again. 2. Clean the lint filters and empty the condensate container. 3. Start a short program and see whether F156 returns. 4. If it does, stop and call us. The sensor sits in the sealed heat-pump section, so leave every panel on.

! Why to stop there
  • The condenser area belongs to the sealed refrigerant circuit, which owners must not open.
  • A shorted sensor and chafed wiring give the same reading, so we measure to tell them apart.
  • Our price is written down before any parts are ordered.
  • Every repair has a 30-day workmanship warranty.
Opening a panel yourself does not automatically cancel a manufacturer warranty, but it can cause accidental damage, and some manufacturers set their own service conditions. Check your warranty terms, or ask us, before deciding.

Technical reference

Code
F156
Appliance
Miele dryer
Checked
October 2026

We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Miele.

F156F156 questions
Which sensor does F156 refer to?

The refrigerant temperature sensor that sits after the condenser in the heat-pump loop. F157 is the open-circuit version of the same sensor, so the two codes are close cousins.

Does the dryer still dry with F156 showing?

No. The control stops the program because it cannot rely on that temperature reading. Hang the laundry for now and avoid starting repeated cycles, since the dryer will keep stopping.

Could clogged filters have caused it?

Clogged filters raise temperatures, but F156 names an electrical short in the sensor. Clean filters are good practice, yet they will not remove this code.