Error code · Cooktop

Miele Gas Cooktop Message “In-operation indicator flashing”: LP gas not supplied

On Miele KM 2xxx and KM 3xxx gas cooktops, a flashing in-operation indicator means liquid propane gas is not being supplied. The cure is to open the gas safety valve, turn all knobs to off, and…

Medium · inspection needed
Code
In-operation indicator flashing
Appliance
Cooktop
Brand
Miele
Warranty
30-day workmanship

What In-operation indicator flashing means

On Miele KM 2xxx and KM 3xxx gas cooktops, a flashing in-operation indicator means liquid propane gas is not being supplied. The cure is to open the gas safety valve, turn all knobs to off, and then reset the power if needed. If you ever smell gas, leave the house at once and call the gas utility from outside. Burners that will not stay lit often come with this message.

Common causes of In-operation indicator flashing

  • The LP gas safety valve is closed
  • The propane supply is empty or interrupted
  • Gas is not reaching the burners for another reason
✓ One safe check you can try

1. Turn every knob to off. 2. If you smell gas, leave the house and call the gas utility from outside; do not operate any switch. 3. If there is no smell, check that the gas safety valve is open and the propane tank is not empty. 4. Reset power at the breaker for a minute. 5. Relight a burner. If the indicator still flashes, call us.

! Why to stop there
  • Gas supply work and conversions must be done by a trained technician
  • A wrong fix with gas can be dangerous
  • We quote in writing first and provide a 30-day workmanship warranty
Opening a panel yourself does not automatically cancel a manufacturer warranty, but it can cause accidental damage, and some manufacturers set their own service conditions. Check your warranty terms, or ask us, before deciding.

Technical reference

Code
In-operation indicator flashing
Appliance
Miele cooktop
Checked
October 2026

We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Miele.

In-operation indicator flashingIn-operation indicator flashing questions
Is a flashing indicator dangerous?

The message itself only says no LP gas is arriving. The danger is gas smell. If you smell gas, leave the house and call the gas utility from outside.

Where is the gas safety valve?

It is on the supply line to the cooktop, often in the cabinet or near the tank. If you cannot find it, we can show you during a visit.

Can an empty propane tank cause this?

Yes. Check the tank first. If it has gas and the valve is open, we test the supply line and the cooktop. We also check the regulator and hose connection during the visit.

Book a visit

Still seeing In-operation indicator flashing?

A technician diagnoses it on site and gives you the price in writing before any work starts.

☎ Call our office ▤ Schedule a Visit