What F14 means
F14 on Miele G 1000, G 2000 and G 5000 Futura dishwashers, for example the G 2430 or G 5105, is raised after the water intake. With the circulation pump running, the heater pressure switch should confirm enough water pressure in the heating circuit, and when it does not, the control stops the program and shows F14. The switch protects the heater from running dry, so the machine will not heat until it reports normally.
Common causes of F14
- Heater pressure switch not closing
- Too little water in the circuit because of an intake problem
- Air or a blockage in the circulation path
- Circulation pump weak
1. Switch the machine off and check that the supply valve is fully open. 2. Remove and rinse the filter set in the tub bottom so water can circulate. 3. Restart a short program and listen for the normal fill and pump sounds. 4. If F14 returns, switch it off and call for a visit.
- The pressure switch protects the heater, and bypassing it can burn the element.
- Low water, a blocked path and a failed switch look alike on the display.
- The switch and heater sit in the wet base area.
- A written price comes first.
Technical reference
- Code
- F14
- Appliance
- Miele dishwasher
- Maker documentation
- Miele owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Miele.
Other Dishwasher codes
What is the heater pressure switch for?
It confirms that water is circulating before the heater switches on. Without that confirmation, the control will not heat, which prevents damage to the element.
Do F51 and F52 relate to F14?
They all involve the heater pressure switch. F14 appears after water intake, F51 at the program start check, and F52 when the switch resets during heating. The checks overlap.
Can cleaning the filter fix it?
Sometimes, if restricted circulation was the cause. If F14 returns after a clean filter set, a technician should look at the switch and pump. Nothing starts until you have approved a written price, and the work comes with a 30-day warranty.