Miele Dishwasher Code F19: Flow meter stiff or stuck
On Miele G 1000, G 2000 and G 5000 Futura dishwashers such as the G 2020 SC or G 5575, F19 says the flow meter is stiff and not turning freely. The flow meter counts the…
- Code
- F19
- Appliance
- Dishwasher
- Brand
- Miele
- Warranty
- 30-day workmanship
What F19 means
On Miele G 1000, G 2000 and G 5000 Futura dishwashers such as the G 2020 SC or G 5575, F19 says the flow meter is stiff and not turning freely. The flow meter counts the water that enters the tub, and when its impeller drags or sticks, the control cannot measure the fill. The cycle stops and the display shows F19, often with no visible leak, just a dishwasher that refuses to fill or complete a program.
Common causes of F19
- Flow meter impeller dragging or jammed
- Debris or scale on the flow meter
- Intake filter partly blocked, upsetting the flow
- Flow meter wiring
1. Check that the supply valve is fully open and the inlet hose is not kinked. 2. If your model has an intake filter at the hose connection, switch off power, close the valve, and rinse the filter. 3. Reopen the valve and run a short program. 4. If F19 returns, hold off and call us. Do not open the base.
- The meter sits in the pressurized intake path beside mains wiring.
- A scaled meter and a damaged wiring link look the same.
- Forcing the impeller can crack the housing.
- We check the intake first and quote in writing.
Technical reference
- Code
- F19
- Appliance
- Miele dishwasher
- Maker documentation
- Miele owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Miele.
Other Dishwasher codes
What does the flow meter do?
It measures the water entering the tub by counting turns of a small impeller. If the impeller is stiff, the count is wrong and the control stops the program.
Does F19 overlap with F12?
They are close. F12 and F13 concern too little flow counted, while F19 says the meter itself is stiff. The checks overlap, so we test both on site.
Can hard water cause it?
Scale and debris can slow the impeller. A clean intake filter helps, but a stuck meter needs a technician. The estimate is put in writing first. After the repair, 30 days of workmanship coverage apply.
Still seeing F19?
A technician diagnoses it on site and gives you the price in writing before any work starts.