Miele T1 Code F157: sensor downstream of the condenser open
Miele T1 heat-pump dryers, including the TXR 860 WP and TWB 120 WP, display F157 when the refrigerant temperature sensor downstream of the condenser is open-circuited. The sensor or its lead has broken the circuit, so…
- Code
- F157
- Appliance
- Dryer
- Brand
- Miele
- Warranty
- 30-day workmanship
What F157 means
Miele T1 heat-pump dryers, including the TXR 860 WP and TWB 120 WP, display F157 when the refrigerant temperature sensor downstream of the condenser is open-circuited. The sensor or its lead has broken the circuit, so the control receives nothing from that spot in the heat-pump loop. Without the reading, the dryer will not continue a program and holds F157 on the display.
Common causes of F157
- An open circuit in the sensor after the condenser
- A broken wire or loose connector on that sensor
- A control input that no longer receives the sensor signal
1. Turn the dryer off and wait a minute before turning it on. 2. Make sure both lint filters are clean and the condensate container is empty and seated. 3. Try a short program. 4. If F157 returns, stop and book a visit. Please do not remove the lower panel or handle the heat-pump section.
- Open versus shorted sensors need a meter to separate, and the meter needs access to the sealed section.
- A loose connector can mimic a dead sensor, and we check that before replacing anything.
- The price comes in writing before work starts.
- We back repairs with a 30-day workmanship warranty.
Technical reference
- Code
- F157
- Appliance
- Miele dryer
- Maker documentation
- Miele owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Miele.
Other Dryer codes
How does F157 differ from F156?
Both involve the sensor after the condenser. F156 says it is short-circuited, F157 says the circuit is open. Either way the control loses a trustworthy reading and stops.
Is it worth restarting several times?
One restart is fine. If the code returns, further tries only repeat the same stop. The wiring or sensor will not heal itself, so a technician has to measure it.
Can this be fixed in one visit?
Often yes, once the sensor or connector is confirmed and the part is available. We diagnose first and tell you the cost in writing before replacing anything.
Still seeing F157?
A technician diagnoses it on site and gives you the price in writing before any work starts.