Most common issues on this model
- Clogged lint filter or vent duct leaving loads damp
- Heater element or its thermal cutout going bad
- Drum glides and rollers wearing and rumbling
- Door latch not registering a closed door
The T 1302 is a 24″ vented electric dryer from the Touchtronic series, wired for 120/208-240 V, 60 Hz at 15 A. In most homes it sits in a laundry closet or a hall alcove, where the duct run to the outside wall decides how well it dries. A long or crushed duct is the first thing we look at when a load takes two cycles.
After the vent, we check the lint filter and the housing behind it, then measure the heating element and the thermal protector. Rumbling usually points to worn drum glides or rollers, and a cycle that will not start points to the door latch. Before we replace anything you get a written price, and our completed repairs carry a 30-day workmanship warranty.
Key features
- Vented electric dryer (Touchtronic series)
- 120/208-240 V, 60 Hz
- 15 A
- 24" wide
Error codes this model can show
My T 1302 runs but clothes stay damp. Where do you start?
With airflow. We disconnect the duct and measure how much air leaves the dryer, because a blocked vent mimics a failed heater. If airflow is good we test the heating element and the protector.
What power does a T 1302 need?
The supply it expects is 120/208-240 V, 60 Hz at 15 A. We confirm the outlet voltage and the cord condition during a visit, because low voltage or a worn connection can reduce heat without any part failing.
The drum makes a rumbling noise. Is that dangerous?
It is not dangerous, but it gets worse. Worn glides or rollers let the drum drag on its support. We replace the worn parts before they damage the drum edge or the felt seal.
Book repair for your T 1302
Book online in about a minute, or give us a call. Same-day appointments are available inside the Loop on most days, and next-day service across the rest of Houston.